{"product_id":"steris-amsco-eagle-series-small-sterilizer","title":"Amsco Eagle 3013 Small Sterilizer","description":"\u003cp\u003e\u003cspan style=\"color: #000000; font-size: 14px; text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-align: left; text-transform: none; text-indent: 0px; letter-spacing: normal; font-family: 'Lato',sans-serif; font-style: normal; font-variant: normal; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; -webkit-text-stroke-width: 0px; background-color: #ffffff;\"\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eOur Remanufactured Steris® Eagle Series sterilizers are equipped with Stage 3 Controls, Impact Printer, Hinged Front Cabinet Panel, Resistance Temperature Detectors, Automatic Utilities Startup\/ Shutdown, Steam Bleed, Steam Purge, Internal Battery Back Up for cycle memory, and Pressure Relief Value.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-align: left; color: #000000; text-transform: none; text-indent: 0px; letter-spacing: normal; font-family: 'Lato',sans-serif; font-size: 14px; font-style: normal; font-variant: normal; font-weight: 400; text-decoration: none; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; -webkit-text-stroke-width: 0px; background-color: #ffffff;\"\u003eFor efficient, high-volume processing of heat-and moisture-stable materials, such as fabrics, wrapped hard goods, glassware or animal bedding at 270Ëš to 280ËšF (132Ëš – 138ËšC). Prevacuum also provides gravity-type cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAvailable in single and double door, pass-through options.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000; font-size: 14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-align: left; text-transform: none; text-indent: 0px; letter-spacing: normal; font-family: 'Lato',sans-serif; font-style: normal; font-variant: normal; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; -webkit-text-stroke-width: 0px; background-color: #ffffff;\"\u003eInterior Chamber Dimensions \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000; font-size: 14px;\"\u003e\u003cspan style=\"text-align: left; text-transform: none; text-indent: 0px; letter-spacing: normal; font-family: 'Lato',sans-serif; font-style: normal; font-variant: normal; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; -webkit-text-stroke-width: 0px; background-color: #ffffff;\"\u003e16 x 16 x 26\" (406 x 406 x 660mm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000; font-size: 14px; text-decoration: underline;\"\u003e\u003cspan style=\"text-align: left; text-transform: none; text-indent: 0px; letter-spacing: normal; font-family: 'Lato',sans-serif; font-style: normal; font-variant: normal; word-spacing: 0px; display: inline !important; white-space: normal; orphans: 2; float: none; -webkit-text-stroke-width: 0px; background-color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; color: #212121; font-family: \u0026amp;quot; lato\u0026amp;quot;,sans-serif; font-size: 14px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; margin-bottom: 10px; margin-top: 0px; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eStage 3 Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eMicrocomputers monitor and control system operations and functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eCycle progress automatically through con­ditioning, sterilizing, exhaust (fast or, for liquids, adjustable-slow with accelerator) and drying phases.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eControl indicates cycle completion visually and also audibly for 90 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eTimers also reset if sterilizer temperature drops 2° F (1.1 °C) below setpoint during the exposure phase.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eControl features programmed sterilize-temperature parameters that prevent inadvertent selection of cycles with improper sterilize-temperature settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf an invalid steril­ize-temperature is selected, a cycle cannot be started and a reference message is furnished.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eA vertical column, mounted on side opposite door hinge, houses the controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eSide-mounting makes controls easy to access and it removes them from exposure to the continuous heat, vapor, and condensate resulting from the sterilization process.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"box-sizing: border-box; color: #212121; font-family: \u0026amp;quot; lato\u0026amp;quot;,sans-serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; margin: 0px 0px 10px 0px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eVacamatic Sterilizer Control\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"box-sizing: border-box; color: #212121; font-family: \u0026amp;quot; lato\u0026amp;quot;,sans-serif; font-size: 14px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; margin-bottom: 10px; margin-top: 0px; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eProvides operator initi­ated automatic Vacuum Test and DART Bowie­ Dick Test Cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eVacuum Test checks the integrity of the piping system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box;\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eDART (Bowie-Dick) Test assures that cycles meet air removal requirements for porous load processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ñý¼§Ö±²¥ Medical Services","offers":[{"title":"Default Title","offer_id":30737836179505,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0049\/2430\/9553\/products\/Amsco_Eagle_3000_288ae38f-0d78-43ab-a26c-d5207eeb98af.jpg?v=1572378512","url":"https:\/\/americanmedservices.com\/products\/steris-amsco-eagle-series-small-sterilizer","provider":"Ñý¼§Ö±²¥ Medical Services","version":"1.0","type":"link"}